Шинэ эрчим хүчний тээврийн хэрэгсэлд шингэн хөргөлтийн системийг хэрхэн сонгох вэ? Батарей, цахилгаан хөтөч

2026-11-09

New-energy vehicles (BEV, PHEV) rely on liquid cooling to remove heat from the battery pack, e-drive and power electronics. The liquid-cooling pipeline is the "blood vessel" of this system -- wrong medium compatibility or insufficient anti-vibration leads directly to coolant leakage, larger cell-temperature spread and even thermal-runaway risk. This article reviews the key parameters and common pitfalls of in-vehicle liquid-cooling pipelines from an engineering-selection perspective.

1. See the medium and duty window first

  • The mainstream coolant is water-glycol solution, commonly 50:50 by volume (i.e. 1:1), concentration range about 20%-50%; more eco-friendly propylene-glycol solution is also used.
  • The battery's optimal operating-temperature window is about 25-35 C; the system allows a wide span: from -30 C (northern winter / semi-trailer) to +65 C, with some quick-coupling elements rated -40 C to +120 C.
  • When battery is below -15 C or above 50 C, the BMS actively derates for protection -- if the pipeline cannot carry the heat away, range and fast-charge efficiency both drop.

2. Pressure is low, but flow and uniformity must qualify

  • The vehicle battery-pack cooling loop is a low-pressure system; working pressure is mostly 0.15-0.35 MPa (some quick-coupling elements rated 0.5-1.6 MPa; industrial test / chiller units up to 0.8-2.5 MPa).
  • Single pack cooling flow is typically 8-15 L/min; engineer by "0.8-1.2 L coolant per kWh, one circulation within 60-90 seconds."
  • The key is not single-point flow but cell-temperature spread: keep Pack DeltaT within 5-8 C, otherwise local aging accelerates and life diverges.

3. Anti-vibration and anti-loosening are the number-one hard metrics on vehicle

  • Driving vibration is the main cause of in-vehicle pipeline and quick-coupling failure. The mainstream approach is FKM rubber hose + wire-braid reinforcement layer, plus 24 deg bite-type fitting (DIN 2353 / ISO 8434-1) to prevent loosening.
  • Quick couplings must pass automotive-grade random-vibration tests (e.g. ISO 22468: 15 Hz-2 kHz, ~0.04 g2/Hz random vibration, withstanding 100+ G shock).
  • Selection iron rule: quick-coupling rated pressure at least 1.5x the system's maximum pressure (e.g. 60+ psi element for a 40 psi circuit).

4. Medium compatibility: don't let seals and tubing "be dissolved"

  • Water-glycol solution pairs with FKM or hydrolysis-resistant PA12: FKM resists glycol degradation, PA12 resists hydrolysis, more stable long term.
  • If dielectric coolant is used in e-drive / power electronics, avoid brass parts to prevent ion contamination; prefer PPSU body or 316L stainless steel.
  • Verify seal medium resistance by ASTM D471 immersion test; don't decide by feel.

5. Cleanliness and dry-break quick couplings: service without leakage or contamination

  • Battery cooling loops demand very high cleanliness (reference VDA 19: particles <=1000 um, total particle mass <=80 mg/L); impurities wear cells and water pumps.
  • Dry-break quick couplings (with automatic shut-off valve) don't leak or admit air on connect/disconnect, operable one-handed with a "click" confirmation; high-flow type up to 60 L/min, pressure drop <=0.25 bar, requiring >=500 mating cycles.
  • Interface protection rating IP68, salt spray 720 h (ISO 9227) or above, for chassis wading and coastal duty.

6. Quick selection checklist

  • Confirm medium: water-glycol (FKM/PA12) or dielectric fluid (PPSU/316L).
  • Confirm temperature window and system maximum pressure; choose quick-coupling rating by 1.5x.
  • Confirm flow (8-15 L/min/Pack) and allowable Pack DeltaT (<=8 C).
  • Confirm vibration grade (ISO 22468) and anti-loosening structure (bite-type fitting / wire braid).
  • Confirm cleanliness grade (VDA 19) and protection (IP68, salt spray 720 h).
  • Confirm dry-break coupling, mating life (>=500 cycles) and one-handed maintainability.

---

About Shanghai Beirun Hydraulic Equipment Co., Ltd. (KUNGFLEX / Kongfu)

  • 17 years dedicated to the hydraulic fluid-connection industry, certified to ISO 9001:2015.
  • Authorized distributor for Gates, and distributing international hydraulic brands such as Parker, Manuli, SPIR STAR, Polyhose, ALFAGOMMA, Eaton.
  • In-house 4000 kg / approx. 400 MPa ultra-high-pressure hose-assembly burst test rig, with verification capability up to about 10x working pressure.
  • Main products: hydraulic hose assemblies, industrial fittings, quick couplings, ball valves, steel-tube assemblies; also expanding into the SQ300 liquid-cooling connector series (316L, helium mass-spectrometer leak detection, 5000-cycle durability) and hydrogen pipeline solutions.
  • Products exported to 80+ countries, serving construction machinery, semiconductor, energy storage, new energy and more.
  • Hotline: 400-820-9728 / 13391148566
  • Address: Building 2, Room 101/201, No. 4777 Jiasong North Road, Jiading District, Shanghai