A concrete pump truck has two different hose systems: the abrasion-resistant delivery hose that carries concrete and the high-pressure hydraulic hose that drives the boom. Their standards and pressure logic differ, and mixing them up leads to burst pipes. Based on EN 12001 and EN 856 4SH, this article sets out the selection parameters and replacement points for both lines to help reduce blocked lines, burst pipes and downtime.
1. Tell the two systems apart: delivery hose and hydraulic hose are not the same
- The delivery hose carries concrete from the pumping unit to the placing end; the medium is abrasive slurry containing sand and gravel, so it is a material conveying pipe
- The boom and pumping hydraulic hoses transmit power; the medium is hydraulic oil, so they are pressure transmission pipes requiring pulse resistance and oil resistance
- Delivery hoses are selected by diameter (DN) and working pressure; pressure is typically 50 to 85 bar depending on the pump output of the machine
- Hydraulic hoses are selected by pressure class and pulse life; the main pump circuit of a pump truck often reaches 32.5 to 42 MPa
- The two cannot be interchanged: using a hydraulic hose to convey concrete wears it through quickly, while using a delivery hose in place of a hydraulic hose bursts due to insufficient pressure rating and pulse resistance
2. Delivery hose selection: diameter, pressure and abrasion are the three hard criteria
- Common diameters are DN50, DN65, DN80, DN100, DN125 and DN150, corresponding to 2 to 6 inches, chosen by pump output and placing radius
- Pressure falls as diameter increases: small-diameter braided hoses are commonly 85 bar, DN125 spiral hoses are often around 50 bar; never apply a small-diameter pressure rating to a larger diameter
- Maximum aggregate size must not exceed one third of the hose inner diameter; for example a DN75 hose allows aggregate up to 25 mm, otherwise blockage is likely
- The inner rubber uses natural rubber NR or a high-wear NR/SBR compound, with abrasion measured by ISO 4649 (formerly DIN 53516) volume loss; quality compounds are below 90 mm3
- The reinforcement uses steel wire braid for small diameters and multi-layer steel wire spiral above DN100; the outer cover must resist weather, ozone and external mechanical damage
- Standard supply lengths are 3 m and 5 m; the proof pressure test is about 1.5 times working pressure and is recorded for each hose

3. Boom hydraulic line selection: high pressure plus high-frequency pulsation, prefer 4SH spiral hose
- The main pumping circuit, boom cylinders and outrigger circuits mostly use EN 856 4SH four-wire spiral high-pressure hose
- Common 4SH pressure ratings: DN19 about 42 MPa, DN25 about 38 MPa, DN32 about 32.5 MPa, DN38 about 29 MPa, with burst pressure four times the working pressure
- Compared with 4SP, 4SH has a better braid angle and smaller bend radius, suiting lines that flex frequently in tight spaces such as boom joints
- Operating temperature typically ranges from -40 C to +100 C; choose an oil-resistant synthetic rubber inner tube and a weather- and abrasion-resistant outer cover
- High-frequency pulsating pump circuits should consider the pulse life class and select anti-pulse products by ISO 18752 class
- Fittings should preferably be crimped carbon steel with zinc or zinc-nickel plating; use zinc-nickel coating in salt-spray environments for better corrosion resistance
4. Connections and accessories: flanges, clamps and quick couplings must match the original machine interface
- Delivery hose ends are mostly flange or clamp connections; common systems such as Schwing and Putzmeister are not interchangeable
- Before purchasing, confirm the original machine's delivery pipe connection type, bore and flange standard to avoid parts that do not fit
- Boom hydraulic lines mostly use 24-degree compression fittings, JIC 37-degree, ORFS or flange connections, selected by the original interface and thread standard
- Reducer hoses are used for diameter transitions; their rated pressure is set by the smaller end and must not be taken from the larger end
- Fittings and seals for delivery and hydraulic lines must be stocked separately, with seal material NBR or FKM selected by medium
5. Failure and replacement: inspect before the hose bursts
- The main failure modes of delivery hose are inner rubber worn through, reinforcement breakage and blocked-line bursts; replacement timing is judged by wall thickness measurement and cumulative pumped volume
- A quality delivery hose can pump about 20,000 cubic metres under normal mixes; life shortens markedly with highly abrasive aggregate, so replace by volume rather than time alone
- The main failures of hydraulic hose are pulse fatigue, outer cover abrasion and fitting leakage; replace immediately if bulging, exposed wire or fitting seepage appears
- Do a visual inspection before each shift, focusing on hose bends, crimped fittings and wear near boom joints
- Delivery hose can withstand reverse negative pressure during cleaning, but must not be reverse-pumped over pressure, to avoid the tube collapsing or fittings coming loose
- During shutdown storage avoid direct sunlight and heavy rolling; coil the hose at its minimum bend radius to prevent sharp folds
6. KUNGFLEX pump truck line package capability
- Can supply concrete delivery hose assemblies to EN 12001 and GB/T 27571, diameters DN50 to DN150, selected by pressure and abrasion duty
- Can supply boom and main pump circuit high-pressure hydraulic hoses to EN 856 4SH and ISO 18752, with matching crimped fittings
- In-house 4000 kg, approx. 400 MPa burst test rig supports strength and reliability verification of assembly batches
- Supplying industrial fittings, quick couplings, ball valves and steel tube assemblies, with complete line packages by machine model
- Distributing Parker, Manuli, SPIR STAR, Polyhose, ALFAGOMMA, Eaton and other brands, able to supply to project standards
- Products exported to 80+ countries, supporting customisation by drawing, by interface and by standard
Quick selection checklist
- [ ] First separate the delivery hose and hydraulic hose systems; confirm medium, standard and pressure logic separately
- [ ] Select delivery hose by diameter and pressure; pressure falls as diameter increases, never apply DN50 rating to DN125
- [ ] Aggregate size must not exceed one third of inner diameter; inner rubber abrasion below 90 mm3 by ISO 4649 is preferred
- [ ] Choose EN 856 4SH for boom and main pump circuits; check pressure ratings from DN19 to DN38 and the 4x burst ratio
- [ ] Match flanges, clamps and hydraulic fittings to the original machine interface; rate reducer hoses by the smaller end
- [ ] Replace delivery hose by cumulative pumped volume, hydraulic hose immediately on bulging or seepage, and inspect visually each shift
About Shanghai Beirun Hydraulic Equipment Co., Ltd. (KUNGFLEX / Kongfu)
- Company: Shanghai Beirun Hydraulic Equipment Co., Ltd. (brand KUNGFLEX / Kongfu)
- 17 years in the industry, certified to ISO 9001:2015
- Authorized distributor for Gates; also distributes Parker, Manuli, SPIR STAR, Polyhose, ALFAGOMMA and Eaton
- In-house 4000 kg / approx. 400 MPa ultra-high-pressure burst test rig (about 10x the working pressure margin)
- Main products: hydraulic hose assemblies, industrial fittings, quick couplings, ball valves and steel-tube assemblies, plus SQ300 liquid-cooling connectors and hydrogen pipeline solutions
- Products exported to 80+ countries
- Hotline: 400-820-9728 / 13391148566
- Address: Room 101/201, Building 2, No. 4777 Jiasong North Road, Jiading District, Shanghai